19052 AC/DC Hipot / Insulation resistance (IR)
CE
19053 AC/DC Hipot / Insulation resistance (IR) / 8HV Channel Scan
UL, TUV, CE |
 |
Specifications
| Model |
19071 |
19073 |
19052 |
19053 |
| Mode |
AC |
AC/DC/IR |
AC/DC/IR |
AC/DC/IR/Scan |
| Scanner Unit |
- |
- |
- |
8 ports,±phase |
| Withstanding Voltage Test |
| Output Voltage |
AC : 0.05 ~ 5kV |
AC : 0.05 ~ 5kV , DC:0.05 ~ 6kV |
| Load Regulation |
1% of setting + 5V |
| Voltage Regulation |
2V |
| Voltage Accuracy |
1% of setting + 5 count |
| Cutoff Current |
AC : 0.1~20mA, DC : 0.01 ~ 5mA |
AC : 0.1~30mA, DC : 0.01 ~ 10mA |
| Current Resolution |
AC : 1µA, DC : 0.1µA |
| Current Accuracy |
1% of setting + 5 count |
| Output Frequency |
50Hz / 60Hz |
| Test Time |
0.3 ~ 999 sec , continue |
| Ramp Time |
0.1 ~ 99.9 sec, Off |
| Fall Time |
0.1 ~ 99.9 sec, Off |
| Waveform |
Sine wave |
| Insulation Resistance Test |
| Output Voltage |
- |
DC : 0.05 ~ 1kV |
| Voltage Resolution |
- |
2V |
| Voltage Accuracy |
- |
5% of setting + 5 count |
1.5% of setting + 5 count |
1.5% of setting + 5 count |
| IR Range |
- |
1MΩ ~ 50GΩ |
1MΩ ~ 50GΩ |
1MΩ ~ 10GΩ |
| Resistance Resolution |
- |
0.1MΩ |
0.1MΩ |
0.1MΩ |
| Resistance Accuracy |
≥500V |
1MΩ ~1GΩ |
- |
4% of setting + 5 count |
5% of setting + 5 count |
5% of setting + 5 count |
| 1GΩ ~10GΩ |
- |
7% of setting + 5 count |
10% of setting + 5 count |
10% of setting + 5 count |
| 10GΩ ~50GΩ |
- |
12% of setting + 5 count |
15% of setting + 5 count |
15% of setting + 5 count |
| ≤500V |
1MΩ ~1GΩ |
- |
7% of setting + 5 count |
10% of setting + 5 count |
10% of setting + 5 count |
| ≤100V |
1MΩ ~1GΩ |
- |
10% of setting + 5 count |
10% of setting + 5 count |
10% of setting + 5 count |
| Flashover (ARC) Detection |
| Setting Mode |
Programmable setting |
| Detection Current |
AC : 1mA ~ 15mA, DC : 1mA ~ 5mA |
AC : 1mA ~ 15mA, DC : 1mA ~ 10mA |
| Secure Protection Function |
| Fast Output Cut-Off |
0.4ms after NG |
| Ground Fault Interrupt |
0.5mA ±0.25mA AC, ON/OFF |
| Panel Operation Lock |
Present password |
| Continuity Check |
1Ω ± 0.2Ω, ON/OFF |
| GO/NG Judgment Window |
| Indication,Alarm |
GO: Short sound,Green LED; NG: Long sound, Red LED |
| Data Hold |
Least tests data memories |
| Memory Storage |
50 instrument setups with up to 20 test steps |
| Interface |
| Remote control |
Input : Start, Stop, Interlock (at 11 pin terminal block only) ; Output : Under test, Pass, Fail |
| Communication Interface |
RS485 (Option) |
RS232 (Standard), GPIB (Option) |
| General |
| Operation Environment |
Temperature : 0°C~40°C, Humidity : 15% to 95% R.H@≤40°C |
| Power Consumption |
300W |
500W |
| Power Requirements |
100V/120V/220V/240V (AC ±10%), 50/60Hz |
| Weight |
Approx. 12KG |
Approx. 15KG |
| Certifications |
UL, TUV, CE |
UL, TUV, CE |
CE |
UL, TUV, CE |
|
 |
19035 AC/DC Hipot, IR, DCR
CE Mark
The 19035 is designed to directly connect to a DWX Series Impulse Winding Tester and use the 8-Channel scanning capabilities to reach multiple points in one test instead of switching test points manually. |
Specifications
| Model |
19035 |
19035-L |
19035-M |
19035-ML |
19035-S |
| Mode |
AC/DC/IR/
DCR -8CH/ IWT |
AC/DC/IR/ DCR -8CH/ IWT |
AC/DC/IR/
DCR -16CH/ IWT |
AC/DC/IR/
DCR -16CH/ IWT |
AC/DCR -8CH |
Impulse Winding Test
(Layer Short, IWT) |
External option |
Internal standard |
External option |
Internal standard |
- |
| Channel Programming |
H/L/X in 8CHs |
H/L/X in 8CHs |
H/X in CH 1,2,3,5,6,7
L/X in CH 4,8 |
H/X in CH 1,2,3,5,6,7
L/X in CH 4,8 |
H/L/X in 8CHs |
| Withstanding Voltage Test |
| Output Voltage |
AC: 0.05~5KV / DC: 0.05~6KV |
| Load Regulation |
±(1% setting + 0.1%full Scale) |
| Voltage Regulation |
2V |
| Voltage Accuracy |
1% setting + 0.1% full Scale |
| Cutoff Current |
AC: 30mA / DC: 10mA |
| Current Resolution |
AC: 1µA / DC: 0.1µA |
| Current Accuracy |
1% of reading + 0.5% of range (1% of reading + 5% of total current) |
| Current Frequency |
50Hz / 60Hz |
| Test Time |
0.1 ~ 999 sec , continue |
| Test / Ramp / Fall / Dwell Time |
0.3 ~ 999 sec., continue / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off / 0.1 ~ 999 sec., off |
| Wave Form |
Sine wave |
| Insulation Resistance Test |
| Output Voltage |
DC : 0.05 ~ 5kV |
| Voltage Resolution |
2V |
| Voltage Accuracy |
1% of setting + 0.1% of full range |
| IR Range |
1MΩ ~ 50GΩ |
| Resistance Resolution |
0.1MΩ |
| Resistance Accuracy |
≧1000V |
0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range) |
| 500V~1000V |
0.1MΩ ~ 1GΩ : ± (3% of reading + 0.1% of full range)
1GΩ ~ 10GΩ : ± (7% of reading + 2% of full range)
10GΩ ~ 50GΩ : ± (10% of reading + 1% of full range) |
| ≦500V |
0.1MΩ ~ 1GΩ : ± 3% of reading + (0.2*500/Vs)% of full scale |
| DC Resistance Measurement |
| Test Signal |
<DC 10V. < DC 100mA |
| Measurement mode |
2 terminals (2W) / 4 terminals(4W) measurement selectable |
Measurement Accuracy
(2W/ 4W) |
1Ω (4W only) |
±(0.5% of reading + 0.5% of range) |
| 10kΩ |
± (2% of reading + 0.5% of range) / ± (0.5% of reading + 0.05% of range) |
| 100kΩ |
| 1kΩ |
| 10kΩ |
| 100kΩ |
| Flashover Detection |
| Setting Mode |
Programmable setting |
| Detection Current |
AC : 1mA ~ 15mA, DC : 1mA ~ 10mA |
| Secure Protection Function |
| Fast Output Cut-off |
0.4ms after NG happen |
Ground Fault Interrupt
|
0.5mA ±0.25mA AC, ON/OFF |
| Panel Operation Lock |
Present password |
| Interlock |
YES |
| GO/NG Judgment Window |
Indication, Alarm
|
GO : Short sound, Green LED; NG : Long sound, Red LED |
| Data Hold |
Least tests data memories |
| Memory Storage |
50 instrument setups with up to 20 test steps |
| Interface |
| RS232*1 (Standard), RS232*1 or GPIB & Handler & Temperature interface (Optional). |
| General |
| Operation Environment |
Temperature : 0°C~45°C, Humidity : 15% to 95% R.H@≦40°C |
| Power Consumption |
500VA |
| Power Requirements |
90~132Vac or 198~264Vac, 47~66Hz |
| Weight |
Approx. 20KG |
|
The 19032 series Safety Analyzer able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032's open / short check function (OSC) checks for an open connection or a DUT short during testing. Open connections may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.
|
 |
| Model |
19032 |
19032-P (Coming soon) |
| Difference at a glance |
--- |
GFI Human Protection / Floating Curcuit Funtion / Mass Power Hipot Output Test 500VA |
| Softpanels (software) |
Yes |
Yes |
| Mode |
AC / DC / IR / GB / LC |
| Withstanding Voltage Test |
| Output Voltage |
DC:0.05 ~ 6kV , AC : 0.05 ~ 5kV |
| Load Regulation |
±(1% of reading +0.1% of range) |
±(1% of reading +0.1% of range) |
| Voltage Regulation |
2V |
| Voltage Accuracy |
±(1% of reading +0.1% of range) |
±(1% of reading +0.1% of range) |
| Cutoff Current |
DC : 20mA , AC : 40mA |
DC : 20mA , AC : 100mA |
| Current Resolution |
0.1 μA DC |
| Current Accuracy |
±(1% of reading +0.1% of range) |
±(1% of reading +0.1% of range) |
| Output Frequency |
50Hz / 60Hz |
| Test Time |
0.3 ~ 999 sec , continue |
| Ramp Time |
0.1 ~ 99.9 sec, Off |
| Fall Time |
0.1 ~ 99.9 sec, Off |
| Waveform |
Sine wave |
| Insulation Resistance Test |
| Output Voltage |
DC : 0.05 ~ 1kV |
| Voltage Resolution |
2V |
| Voltage Accuracy |
±(2% of reading +0.5% of range) |
±(2% of reading +0.5% of range) |
| IR Range |
1MΩ ~ 50GΩ |
| Resistance Resolution |
0.1MΩ |
| Resistance Accuracy |
5% typical |
| Ground Bond Test |
| Output Current |
AC : 1 ~ 30A (40A, 60A optional) |
AC : 3 ~ 40A (60A optional) |
| Current Accuracy |
±(1% of reading +0.2% of range) |
±(1% of reading +0.2% of range) |
| GR Range |
10mΩ ~ 510mΩ |
| Resistance Resolution |
0.1mΩ |
| Resistance Accuracy |
± (1% of reading + 0.1% of full scale) |
± (1% of reading + 0.1% of full scale) |
| Test Method |
4 wires |
| Flashover Detection |
| Setting Mode |
Programmable setting |
| Detection Current |
AC : 20mA, DC : 10mA |
| Secure Protection Function |
| Ground Fault Interrupt |
--- |
0.5mA ±0.25mA AC |
| Floating Output |
--- |
3.5mA, front output only |
| Panel Operation Lock |
Present password |
| Interlock |
YES |
| GO/NG Judgment Window |
| Indication,Alarm |
GO: Short sound,Green LED; NG: Long sound, Red LED |
| Data Hold |
Least tests data memories |
| Memory Storage |
50 setups with up to 100 groups recall |
| Interface |
| 9pin D-sub I/O control / RS232 / GPIB (Optional) |
| General |
| Operation Environment |
Temperature : 0°C ~ 40°C, Humidity : ± 80 % RH |
| Power Consumption |
No load : < 100 W With rated load : 800 W |
No load : < 100W Rated load : 1000W Maximum load : 1200W |
| Power Requirements |
90~132Vac or 198~264Vac, 47~66Hz |
| Weight |
Approx. 20KG(19032) 25KG (19032-P) |
 |
19572 AC current output 45A
Wide resistance range: 10 ~ 510mΩ
UL, CSA, TUV, VDE, CE
|
| Model |
19572 |
| Mode |
Ground Bond |
| Grounding Resistance Test |
| Output Current |
AC : 3~45 A |
| Load Regulation |
1% + 0.3 A |
| Resolution |
3~30A 0.01A / 30.1~45A 0.1A |
| Current Accuracy |
±(1.5% of setting + 0.5% of full scale) |
| Output Frequency |
50Hz / 60Hz |
| Resistance Range |
0.1 ~ 510 mΩ |
| Resistance Resolution |
R display counts/ I display counts) >0.2, Resolution : 1mΩ
(R display counts/ I display counts) <0.2, Resolution : 0.1mΩ |
| Resistance Accuracy |
±(2% of reading + 0.5% of full scale) |
| Offset |
- A predetermined value can be substracted from the measured value and the result of substraction can be displayed.
- The result of subtraction can be compared with a Good/No Good judgement reference value, and the result of the comparison can be used for the judgement. |
| Offset Range |
0 ~ 100 mΩ |
| Test Time |
0.5 ~ 999.0 sec., continue |
| Waveform |
Sine Wave |
| GO/NOGO Judgment |
- A no-good judgement is made when a resistance greater that the high limit value is detected.
- A no-good judgment is made whne the output current is cutout and a no-good alarm signal is delivered.
- If no abnormal state is detected during the test time, a good judgment is made and a good signal is delivered. |
| Limit |
HI-LIMIT : 0.1 ~ 510 mΩ
LOW-LIMIT: OFF, 0.1 ~ HI-LIMIT Value 510 mΩ MAX. |
| General |
| Operation Environment |
Temperature : 0°C~40°C (32° to 104° F), <80% R.H |
| Power Consumption |
No load: < 100VA; with rated load: 880W MAX. |
| Power Requirements |
100V / 120V / 220V-10% / 240V-10% ~ +5% |
| Weight |
< 16 kg |